CB Tooling Detail
| Nomimnal Hole Size | 1 15/64 |
| Mandrel Tool Code | 38-3-N |
| Start Hole Max | 1.19 |
| Start Hole Min | 1.18 |
| Final Hole Max | 1.25 |
| Final Hole Min | 1.23 |
| Start Drill1 | WCI-SD-38-3-N |
| Start Reamer2 | WCI-SR-38-3-N |
| Combination Gage | WCI-CBG-38-3-N |
| Mandrel Wear Gage | WCIS-WG-38-3-N |
| Mandrel3 | WCI-CBM-38-3-N-*-XX |
| Extension Nosecap4 | WCI-1900NE-38-3-XXF |
| Flush Nosecap5 | WCI-1900N-38X |
| Sleeve6 | CBS-38-3-N-XX * |
| Finish Reamer7 | WCI-FR-38-3-N-XXXX |
| Optional Tooling |
| Start Hole Gage | WCI-SHG-38-3-N |
| Final Hole Gage8 | WCI-FHG-****-XXXX |
« Return to overview.
- 1 - Start Drill
- Add -C if cobalt
- 2 - Start Reamer
- Add -C if cobalt
- 3 - Mandrel
- * = Attachment callout
- 1 = 7/16-20 used with 1700 puller to 16-3-N
- 2 = 5/8-18 used with 1800 puller, 10-3-N - 30-3-N
- 3 = .960 tang used with 1900 puller 32-0-N - 56-3-N
- 4 = 7/8-14 used with 1900 puller, 32-0-N - 56-3-N, 2 piece
- 5 = 7/8-14 used with 1800 puller
- XX = Mandrel length in 1/10". Available in ½" increments
- Add -V2 for high strength steel and titanium application
- 4 - Extension Nosecap
- XX = Extension length in 1/10". Available in ½" increments
- ****= (Overlap between 1700 and 1800 pullers. Please specify)
- 5 Flush Nosecap
- X = (F)lared or (S)traight sleeve
**** = (overlap between 1700 and 1800 pullers. Please
specify)
- 6 Sleeve
- XX = Sleeve length in 1/16"
* = (F)lared or (S)traight sleeve
- 7 Finish Feamer
- XXXX = Final hole size in 1/10,000". Add -C if Cobalt
- 8 Final Hole Gage
- **** = Go diameter
XXXX = No-Go diameter